• Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
  • Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
  • Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
  • Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
  • Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
  • Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System

Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System

After-sales Service: Life-Long Maintaince
Warranty: 1 Year
Connectors: USB
Samples:
US$ 8500/Set 1 Set(Min.Order)
| Order Sample
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System pictures & photos
Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
US $7,600-8,000 / Set
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • FAQ
  • Contact us
Overview

Basic Info.

Model NO.
HTXZ-
Test Mode
One-sided Test
Usage
Coaxial Cable Tester, Digital Cable Tester, Hv Cable, Gis, Transformer, Substation Trasformer
Test Region
Forming Cable
Power
Electricity
Certification
CE, RoHS, ISO
Customized
Customized
Color
Red
Lead Time
Usually 20-30 Days
Shipment
by Sea, Denpend on Customer′s Choice
Online Teachment
Available
Comply Standard
GB 50150-2016, Dl/T 849.6-2016, Dl/T 474.4-2018
Structures
Power Source, Excitation Transformer, Reactors
Working Frequency
30-300Hz
Device Output Waveform
Sine Wave
Waveform Distortion Rate
Output Voltage Waveform Distortion Rate <1%
Working Time
Continuous 60min Is Allowed Under Rated Load; Over
Temperature Rise
<65K After Continuous Operation Under Rated Load
The Quality Factor
Q>30(F=45Hz)
Protection Function
Over Current, Over Voltage and Flashover Protectio
Accuracy of Measurement
Effective Value of The System Is 1.5
Environment Temperature
-100-50 Celsius Degree
Application
Substation Equipment
Transport Package
Wooden Case
Specification
see details
Trademark
HV TEST
Origin
China
HS Code
9030899090
Production Capacity
60 Sets Per Month

Packaging & Delivery

Package Size
1180.00cm * 232.00cm * 236.00cm
Package Gross Weight
150.000kg

Product Description

HTXZ-324KVA/162kV AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
Product Description

HTXZ series variable frequency resonant device is a common primary electrical equipment of substations. It is applied for voltage withstand test of capacitive equipment, such as transformer, GIS system, SF6 switch, CT/PT, insulator, busbar, cable and bushing ect. This device is researched and manufactured according to withstand test regulations of 220KV and blow substations primary electrical equipment. The AC/DC voltage withstand test equipment both need satisfy high voltage, small current and low voltage, large current test condition, and with wide application range. HTXZ using the principle of series resonant, is composed by variable frequency power source control box(console), excitation transformer, reactor and capacitive voltage divider,compensating capacitor.

Technique parameters

Rated Capacity 324kVA
The input power Three-phase 380V voltage, frequency: 50Hz
Rated Voltage 54kV
Rated current 6A
Working frequency 30-300Hz
Device output waveform Sine wave
Waveform distortion rate Output voltage waveform distortion rate ≤1%
Working time Continuous 60min is allowed under rated load; Overvoltage 1.1 times 1 min
Temperature rise Temperature rise ≤65K after continuous operation under rated load for 60min
The quality factor Device Q≥30(f=45Hz)
Protection function Over current, over voltage and flashover protection (see frequency conversion power supply for details)
Accuracy of measurement Effective value of the system is 1.5
Environment temperature -100oC-50oC
Relative humidity ≤90%RH
The altitude ≤1000m

Excitation transformer

Rated Capacity 9kVA
The input voltage 0-400V,Single phase
The output voltage 3kV
structure dry type
Weight About 50kg

AC power supply

Rated output capacity 18kW
Working power supply 380±10%V (three-phase), power frequency
The output voltage 0-400v, single phase
Rated input current 45A
Rated output current 45A
Voltage resolution 0.01kV
Accuracy of voltage measurement 1.5%
Frequency range 30-300Hz
Frequency regulation resolution ≤0.1Hz
Frequency stability 0.1%
Running time Continuous 60min at rated capacity
Noise level ≤50dB
High voltage reactor
Rated Capacity 54kVA
Rated Voltage 27kV
Rated Voltage 2A
inductance 68 H/single section
The quality factor Q≥30(f=45Hz)
structure dry type
Weight About 75kg
Capacitor Divider
Rated voltage 60kV
High piezoelectric capacity 2500pF
Dielectric loss tgσ≤0.5%
Voltage division ratio 1000:1
measurement accuracy Valid value of 1.5
Weight About 10kg
 
Detailed Photos

Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System

Company Profile

Wuhan Huatian Electric Power Automation CO., LTD Established in 1992. we are located in Wuhan East Lake High-Tech Development Zone, which is also named Wuhan Optical Valley with convenient transportation access.
Huatian Electric Power is a well-experienced OEM/ODM factory engaged in the research, development, manufacture, sale and service of electric power testing equipment or systems.Including AC Series Resonant Test System, AC/DC/VLF Hipot Test Set, Transformer Tester, Secondary Injection Relay Tester, Cable/Line Tester, Insulation Oil Tester, Circuit Breaker/Switch Tester and SF6 Test Equipment etc.

They are widely used in electric power,energy, transportation,metallurgical,chemical,mining and water conservancy project. We have obtained the ISO 9001 quality system certification, OHSAS 18001:2007 Occupational Health and Safety Management System certification and all products conform to the international CE or Chinese state standards.
 
Our products are widely exported to all over the world and our service are recognized and highly appreciated by world scale customers, we will always right be here take the customer as first priority and provide you the best solution. Looking forward to building a thrust-worthy and long-term relationship with you.


Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test SystemHtxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System

FAQ

 

1. Is your company a sales company or a manufacturer?

Wuhan Huatian Electric Power Automation CO., LTD.is an industrial and trade enterprise, with its own factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. When can i get the price ?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or send us your email so that we can provide you the details at our first time.

3.What is your terms of delivery ?

We accept EXW, FOB, CFR, CIF ect. You can choose the one which is the most convenient and cost effective for you.

4. How much will be the Shipping cost and time?

This will depend on the size and quality of the goods you purchased and the method of shipping(by sea/ by air/ by Epress) and your designated port or air port. We will be grateful of you can spare us some times to evaluate the cost based on the information provided.

5. Could you please tell me the Warranty Period of your product ?

Our warranty period is one year free and lifelong maintance, and if the product is damaged (if not man-made damage),
in the first year, we will send free parts for replacement or free repairment if you willing to send back the equipment (customer will take the shipment cost).

6.What kind of Certificate can you provide ?

We can provide the CE mark, ISO 9001 quality certificate, the third party calibration certificate(CNAS), factory test report.

7.Do you have Technique support to all customers from different countries ?

To be frankly, our techinical support is always avaliable and quick response in 12 hours. We are manufacturer of so much on site testing experience and understand how to deal with your problems.
Contact us

 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System pictures & photos
Htxz-324kVA/162kv AC Frequency Conversion Hipot Dielectric Test System High Voltage Withstand Resonant Test System
US $7,600-8,000 / Set
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Year of Establishment
2021-03-15
Management System Certification
ISO9001:2015, ISO14001:2015
Export Year
2011-07-01