• Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
  • Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
  • Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set

Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set

Warranty: 1 Year
Product Name: Tan Delta Tester
Voltage Range: 0.5-10kv
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set pictures & photos
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
US $3,990-5,200 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
to see all verified strength labels (28)

Basic Info.

Model NO.
HTJS-M
Internal Hv
3PF~60000PF/10kv 60PF~1μf/0.5kv
Power
2kVA
Maximum Output Current
200mA
Frequency Accuracy
±0.01Hz
Input Power
180V~270VAC,50Hz
Computer Interface
Standard RS232 Interface
Temperature
-10~50
External Hv
3PF~1.5μf/10kv 60PF~30μf/0.5kv
Resolution
Max: 0.001PF,4 Digits 
Tgδrange
Unlimited, Resolution of 0.001%
Test Frequency
45,50,55,60,65Hz
Measuring Time
About 40 S
Relative Humidity
<90%
Transport Package
Wooden Case or Carton
Specification
460*360*350mm3
Trademark
UHV
Origin
China
HS Code
9030849000
Production Capacity
200 Sets Per Month

Packaging & Delivery

Package Size
61.00cm * 51.00cm * 64.00cm
Package Gross Weight
53.000kg

Product Description


Introduction

The high-voltage dielectric loss test device is used for on-site anti-interference dielectric loss measurement, or precision dielectric loss measurement in the laboratory. The instrument is an integrated structure with built-in dielectric loss bridge, variable frequency power supply, test transformer and standard capacitors. Using frequency conversion anti-interference and Fourier transform digital filtering technology, automatic and intelligent measurement, the measurement data is very stable under strong interference. The measurement result is displayed by a large-screen LCD, and the built-in micro-printer can be printed out.
Features

1.2.1 Frequency conversion anti-interference
Using frequency conversion anti-interference technology, it can still measure accurately under 200% interference, and the test data is stable, which is suitable for on-site anti-interference dielectric loss test.

1.2.2 High-precision measurement
Using techniques such as frequency floating, digital waveform analysis, and bridge self-calibration, combined with high-precision three-terminal standard capacitors, high-precision dielectric loss measurement is achieved, and the accuracy and stability of the positive/reverse wiring measurement are consistent.
The input resistance of all ranges of the instrument is lower than 2Ω, which eliminates the influence of the additional capacitance of the test line.
It can be connected to an oil cup for precision dielectric loss test of insulating oil, and can be connected to a solid material measuring electrode for precision dielectric loss test of insulating material.

1.2.3 Good compatibility
Automatic identification of 50Hz / 60Hz system power supply, support generator power supply, even if the frequency fluctuates greatly, it can be measured normally.
The built-in series and parallel dielectric loss measurement models are fully compatible with the calibration table and dielectric loss standard, which is convenient for instrument verification.

1.2.4 Multi-level safety protection to ensure personal and equipment safety
High-voltage protection: short-circuit, breakdown or high-voltage current fluctuations of the test product can cut off the output at a high speed in a short-circuit mode.

Low voltage protection: wrong connection of 380V, power supply fluctuation or sudden power failure, start protection, will not cause overvoltage.

Grounding protection: When the instrument's poor grounding causes the enclosure to carry dangerous voltage, the grounding protection is activated.

C V T: Four protection limits of high voltage and current, low voltage and current, will not damage the equipment; wrong selection of the menu will not output excitation voltage. There is no 10kV high voltage output during CVT measurement.

Misoperation prevention: two-level power switch; real-time monitoring of voltage and current; multiple keystrokes to confirm; terminal high/low voltage is clearly defined; slow boosting, rapid decompression, sound and light alarm.

Anti- "capacity rise": When measuring large-capacity samples, there will be a "capacity rise" effect of increased voltage. The instrument can automatically track the output voltage and keep the test voltage constant.

Anti-seismic performance: The instrument adopts a unique anti-seismic design, which can withstand strong long-distance transportation vibration and bumps without being damaged.

High-voltage cable: It is a high-voltage resistant insulated wire that can be used for mopping the ground.

1.2.5 Technological breakthroughs, powerful functions
(1) With an external standard capacitor interface, it can automatically track the frequency of the external test power supply from 45Hz to 65Hz, and support industrial frequency power supply and series resonance power supply for large-capacity high-voltage dielectric loss test.
 
  1. It has the function of discharging prompt for poor circuit contact to facilitate the judgment of whether the wiring is reliable.
 
  1. With CVT self-excitation method measurement function, C1/C2 can be measured at the same time during one connection, automatically compensate for the effect of bus grounding and the partial voltage of standard capacitors, without changing wires and connecting any external accessories, and high-voltage connecting wires can be grounded.
 
  1. With reverse wiring low-voltage shielding function, when the 220kVCVT bus is grounded, the C11 can be measured without disconnecting the 10kV reverse wiring dielectric loss, and the master and slave capacitors can be measured at the same time for one wiring.
 
  1. Chinese graphic menu, large backlit LCD display.
 
  1. Equipped with thermal printer, printing data is clear and fast, without noise
 
  1. With calendar clock, 100 sets of measurement data can be stored.
 
  1. With computer interface (optional). Through this interface, the measurement, data processing and report output can be realized, and the internal measurement software of the instrument can also be upgraded. A computer can control 32 instruments, which can be integrated into a comprehensive high-voltage test vehicle.

Parameters
 
Accuracy Cx ±(reading×1%+1pF)
tgδ ±(reading×1%+0.00040)
Anti-interference index variable-frequency anti-interference, under 200% interference can still achieve the above accuracy
Capacitance Range internal HV 3pF~60000pF/10kV 60pF~1.2μF/0.5kV
external HV 3pF~1.5μF/10kV 60pF~30μF/0.5kV
resolution Max: 0.001pF,4 digits 
tgδrange Unlimited, resolution of 0.001%, automatically identify the tested samples of capacitance, inductance and resistance.
Test CurrentRange 10μA~5A
Power 2kVA
Internal HV Voltage range 0.5~10kV
Max output current 200mA
Step-up and step-down voltage mode Continuous smooth adjustment
Test Frequency 45,50,55,60,65Hzsingle-frequency
49/51Hz,45/55Hz,47.5/52.5Hz automatic dual variable-frequency
Frequency Accuracy ±0.01Hz
External HV When forward wiring the max test current is 5A, power frequency or variable frequency is 45-65Hz
When reverse wiring the max test current is 10kV/5A, power frequency or variable frequency is 45-65Hz
CVT self-excited method low voltage output Output voltage 3 ~ 50V, output current 3 ~ 30A
Measuring time About 30 s, correlate with the measurement mode
Input Power 180V~270VAC,50Hz/60Hz±1% ,Mains or generator power supply
Computer Interface Standard RS232 interface (Optional)
Printer Comes with mini thermal printer
Temperature -10ºC~50ºC
Relative Humidity <90%



 
Company info

Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set



Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set

Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set

Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set


Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
Common problem
1. Is your company a sales company or a manufacturer?
Wuhan UHV Power Technology Co.,Ltd. is an industrial and trade enterprise, with its own  factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. Whether the goods are in stock, whether they can be customized, and how long the delivery time is.
After the goods have been ordered, it takes about 7 working days for production if there are no accidents.

3. Is the quality guaranteed?
In order to ensure quality, we use imported components in large quantities. After three times of quality inspection, the goods can be sent out, and the export is uniformly packed in non-fumigation wooden boxes.

4. What are the after-sales terms?
We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, technology door-to-door, aiming to solve any after-sales problems in a timely manner.

5. What are the cooperative countries or regions?
Products have been successfully exported to the United States, Brazil, Australia, Russia, the Netherlands, Indonesia, Bangladesh, Iran, India, Saudi Arabia, Mongolia, Japan and other countries and regions. In the United States, India, Vietnam and other regions have cooperative distributors, can provide thoughtful services.



Contact us

Wuhan UHV Power Technology Co.,Ltd.
Address:Building 6, Optics Valley Optical-Mechanical Industrial Park, No.83, Gaoxin 5th Road,
 East Lake High-tech Zone, Wuhan city .China   430223

 










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set pictures & photos
Htjs-M 10 Kv Transformer Dielectric Loss Tester Tan Delta Measurement Capacitance and Dissipation Factor Test Set
US $3,990-5,200 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Year of Establishment
2021-03-15
Management System Certification
ISO9001:2015, ISO14001:2015
Export Year