• Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
  • Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
  • Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
  • Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
  • Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester

Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester

After-sales Service: 1 Year
Warranty: 1 Year
Temperature: -5°c~40°c
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester pictures & photos
Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
US $1,580-2,450 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
to see all verified strength labels (28)

Basic Info.

Model NO.
HTRS-V
Humidity
<95%(25°c)
Altitude
<2500m
Outside Interference
No Exceptionally Strong Vibration, No Extra - Stro
Power Supply
220VAC±10%,45Hz~55Hz.
Current Output
0 ~ 10A
Voltage Measurement
0 ~ 10V
Test Capacity
30kVA ~ 2500kVA
Voltage
0~450V (Phase Voltage), 0 ~ 800V (Line Voltage)
Current
0 ~ 100A
Frequency
45Hz ~ 65Hz
Voltage Accuracy
± 0.2% Fs; ± 0.2%
Current Accuracy
± 0.2% Fs
Dimension
400×300×170mm
Weight
6kg (Not Including Test Lines)
Transport Package
Wooden Case or Carton
Specification
see details
Trademark
UHV
Origin
China
HS Code
9030849000
Production Capacity
200 Sets Per Month

Packaging & Delivery

Package Size
47.00cm * 41.00cm * 40.00cm
Package Gross Weight
19.000kg

Product Description

Brief introduction
HTRS-V can test the transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. It is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers. It is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.
 
Products features
can accurately measure capacity of distribution transformer , convenient and accurate.
Measure the transformer no-load current, no-load loss; short-circuit voltage, short circuit (load) loss, capacity.
The device with auto switching range, allow measure wide range voltage and current, simple wiring;
The device can auto check if the wire was correctly connected, and display the vector diagram of three phase current, voltage when test the three phase transformer.
Single machine can make the loading test for substation transformer under 1000KVA; can make the loading test with 1/3 of the rated current for substation transformer under 3150KVA (the device can convert to the loading losses parameters if the rated current under 1/3 of the rated current)
All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.
320x240 LCD, friendly man-machine interface, brilliance control, adapts to all seasons.
The device can be preset 40 groups parameters of testes objects, and these parameters can be deleted or added at any time as needed, easy to use.
With electronic clock, auto record the data, time, it is good for saving and managing the test results.
Panel type printer can print the test results on site.
Data (specimen setting, test results, measurement time) can be saved on power failure and can be reviewed, it can store 500 groups test results, can connect with computers to transmit data.
Allow external connecting CT and PT to make extension measurement, can test the specimen with any parameters.
Product parameters
Service conditions
Temperature -5°C~40°C
Humidity <95%(25°C)
Altitude <2500m
Outside interference no exceptionally strong vibration, no extra - strong electromagnetic fields.
Power supply 220VAC±10%,45Hz~55Hz.
Main technical parameters
Active parts:
Current output 0 ~ 10A
Voltage measurement 0 ~ 10V
Test Capacity 10KV oil-immersed, dry-type transformers: 30KVA ~ 2500KVA
35KV oil-immersed transformers: 50KVA ~ 31500KVA
20KV dry type transformers: 50KVA ~ 2500KVA
35KV dry type transformers: 50KVA ~ 2000KVA
Features parts:
Voltage 0~450V (phase voltage), 0 ~ 800V (line voltage),auto-switch the measurement range
Current 0 ~ 100A, auto-switch the measurement range
Frequency 45Hz ~ 65Hz
Test accuracy
Voltage  20 ~ 100V, ± 0.2% FS; 100 ~ 450V, ± 0.2%
Current 0.5 ~ 10A, ± 0.2% FS; 10 ~ 100A, ± 0.2%
Power ± 0.5% (CosΦ> 0.1), ± 1.0% (0.02 <CosΦ <0.1)
Dielectric strength The insulation resistance between voltage, current input terminal and the chassis≥100MΩ.
Between power supply input terminal and the shell can withstand  2KV (rms), for 1 minute
Dimension 400×300×170mm
Weight  6kg (not including test lines)
Htrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic Tester
Htrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic TesterHtrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic TesterHtrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic TesterHtrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic TesterHtrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic Tester
Htrs-V China Mainland Manufacturer Transformer Capacity &amp; Short Circuit Loss Characteristic Tester



FAQ
1. Is your company a sales company or a manufacturer?
Wuhan Huatian Electric Power Automation CO., LTD.is an industrial and trade enterprise, with its own  factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. Whether the goods are in stock, whether they can be customized, and how long the delivery time is.
After the goods have been ordered, we can be made to order according to the special requirements of customers by using the latest technology. The delivery time is usually within 10 working days if there are no accidents.

3. Is the quality guaranteed?
In order to ensure quality, we use imported components in large quantities. After three times of quality inspection, the goods can be sent out, and the export is uniformly packed in non-fumigation wooden boxes.

4. What are the after-sales terms?
We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, technology door-to-door, aiming to solve any after-sales problems in a timely manner.

5. What are the cooperative countries or regions?
Products have been successfully exported to the United States, Brazil, Australia, Russia, the Netherlands, Indonesia, Bangladesh, Iran, India, Saudi Arabia, Mongolia, Japan and other countries and regions. In the United States, India, Vietnam and other regions have cooperative distributors, can provide thoughtful services.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester pictures & photos
Htrs-V China Mainland Manufacturer Transformer Capacity & Short Circuit Loss Characteristic Tester
US $1,580-2,450 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Year of Establishment
2021-03-15
Management System Certification
ISO9001:2015, ISO14001:2015
Export Year
2011-07-01