| After-sales Service: | 1 Year |
|---|---|
| Warranty: | 1 Year |
| Storage Conditions: | -10℃~50℃ |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Reference Working Conditions | Temperature | (23±5)ºC |
| Hunidity | (45~75)%RH | |
| Wave forms of measured signal | sine wave,β=0.02 | |
| Frequency of measured signal | (50±0.2)Hz | |
| Position of Measured current carrying conductor in the nipper jaw | Optional position | |
| Amplitude range of measured signal when measuring phase | 100~220V,0.5~1.5A | |
| External reference frequency electromagnetic interference | Should be avoided |
| Table 1:Measurement Error of AC Voltage | ||
| Measure range | Resolution | Limits of intrinsic error |
| 20V | 0.01V | ±(1.0%RD+2) |
| 200V | 0.1V | |
| 500V | 1V | |
| Table 2:Measurement Error of alternating current | ||
| Measure range | Resolution | Limits of intrinsic error |
| 200mA | 0.1mA | ±(1.0%RD+2) |
| 2A | 1mA | |
| 10A | 10mA | |
| Table 3: Measurement Error of Power-frequency Phase | ||
| Range | Resolution | Limits of intrinsic error |
| 0~360° | 1° | ±3° |
| Rated Working Conditions | Temperature | (0~40)ºC |
| Humidity | (20~80)% RH | |
| Wave forms of measured signal | Sine wave,β=0.05 | |
| Frequency of measured signal | (50±0.5)Hz | |
| Position of Measured current carrying conductor in the nipper jaw | Optional position. | |
| Amplitude range of measured signal when measuring phase | Phase U1-U2:30V~500V | |
| Phase I1-I2:10mA~10.00A | ||
| Phase U1-I2 or I1-U2:10V~500V,10mA~10.00A | ||
| External reference frequency electromagnetic interference | should be avoided | |
| Limits of Rated Working Error | Under the conditions described in 1, the limits of the rated operating error will not exceed twice of the limits of intrinsic error. |
| Display | three and half | |
| Sampling rate | 3 times per second | |
| Power supply | Single 9V laminated cell,current of power is less than 5mA | |
| Dimensions | Meter shell | 192×95×55mm3 |
| Clamp shell | 140×42×20mm3 | |
| Nipper jaw | Φ7mm×9mm | |
| Weight | Meter body | 280g |
| Measuring clamps | 2×200g | |
| Storage Conditions | Temperature | -10ºC~50ºC |