Model | test current | Voltage accuracy | short-circuit current |
GM-5kV | 0.1,0.25,0.5,1,2.5,5kV | ±(5%+10V) | 10mA |
GM-10kV | 0.25,0.5,1,2.5,5,10kV | ±(5%+10V) | 10mA |
GM-15kV | 0.5,1,2.5,5,10,15kV | ±(5%+10V) | 10mA |
GM-20kV | 0.5,1,2.5,5,10,20kV | ±(5%+10V) | 10mA |
Range | Effective range of resistance measurement | Accuracy |
20MΩ | 0.01~19.99MΩ | ±(5%+3d) |
200MΩ | 5.0~199.9MΩ | ±(5%+3d) |
2GΩ | 0.05~1.999GΩ | ±(5%+3d) |
20GΩ | 0.5~19.99GΩ | ±(5%+3d) |
200GΩ | 5.0~199.9GΩ | ±(10%+3d) |
2000GΩ | 50~1999GΩ | ±(20%+10d) |
M Ω range calibration voltage is 0.5 kV, G Ω range calibration voltage is 2.5 kV | ||
Test current range to ensure the accuracy of the resistance measurement: above 20% voltage range nominal value | ||
When the test current is higher than 8 kv, for accurately measuring above 20 g Ω resistance, exposed in the air of high voltage electrode conductor should be shielded, avoid air ionization effects | ||
2000GΩthe measurement range is the reference range and is used for relative humidity less than 70% in a dry environment |
Test current level | 0.5kV,1kV,2.5kV,5kV,10kV,20kV | |
Test current precision | ±(5%+10V) | |
Short circuit current | typical value10mA | |
Anti-electric field interference ability | 2mA(50/60Hz) | |
Alarm function | The maximum value of the stopwatch is 19 minutes and 59 seconds, 20 minutes a cycle, sound alarm point for 15 seconds, 60 seconds, per minute, short sound. Keep the resistance reading for 5 seconds, and the measured resistance is lower than the lower limit of the range. When the reading is invalid, alarm will be sounded continuously. |
|
Display table | Three - and - half - bit LCD digital first three, respectively display test current, resistance, time. | |
Power supply | 1.2v /2000mAh nickel metal hydride rechargeable battery 10, DC12V power supply. With an ac (50/60hz)220V connector to charge or float the battery | |
Working environment | temperature:-20ºC~+40ºC ; relative humidity:20%~90% | |
Dimension | 315×240×180mm3 | |
Weight | 5.5kg |