| After-sales Service: | 1 Year |
|---|---|
| Warranty: | 1 Year |
| Standard Voltage: | ±300—±4800 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Charging voltage | Setting range | 0 ~ 100kV |
| Scope of work | 10.0~100.0kV | |
| Setting deviation | ≤±1% | |
| Instability degree | ≤±1% | |
| Setting resolution | 0.1kV | |
| Charging time | Setting range | 30~180s |
| Setting resolution | 1s | |
| Alarm delay | 2s | |
| Number of pressure | Setting range | 1~999 |
| Protection setting | Overcurrent protection value | configurable |
| Overvoltage protection value | configurable | |
| Dynamic charge protection | Can be Selected | |
| Output impact stability | Greater than 99% | |
| Number of voltage boosting | setting range | 1~999 |
|
100kV/5kJ |
||
|
200kV5kJ |
No truncation device, oscilloscope or acquisition card |
6-10KV level switches and insulators; Lightning impulse voltage full wave test, waveform 1.2/50us |
|
200kV10kJ |
No truncation device, oscilloscope or acquisition card |
6-10KV level switches and insulators; And the full wave test of lightning impulse voltage for transformers and mutual inductors without cutoff test requirements, waveform 1.2/50us |
|
200kV10kJ |
There is a truncation device, Tektronix 1102 oscilloscope or acquisition card |
6-10KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
300kV7.5kJ |
No truncation device, oscilloscope or acquisition card |
10-35KV level switches and insulators; Lightning impulse voltage full wave test, waveform 1.2/50us |
|
300kV15kJ |
No truncation device, Tektronix 1102 oscilloscope or acquisition card |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors without waveform cutoff test requirements, waveform 1.2/50us |
|
300kV15kJ |
300kV single-stage cutoff device, oscilloscope or acquisition card |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
300kV30kJ |
300kV single-stage cutoff device, Tektronix 2012 oscilloscope or acquisition card |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
400kV10kJ |
No truncation device, oscilloscope |
10-35KV level switches and insulators; Lightning impulse voltage full wave test, waveform 1.2/50us |
|
400kV20kJ |
400kV single-stage cutoff device, oscilloscope |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
400kV20kJ |
No truncation device, oscilloscope or acquisition card |
10-35KV level switches and insulators; And the full wave test of lightning impulse voltage for transformers and mutual inductors without cutoff test requirements, with a waveform of 1.2/50us; |
|
400kV30kJ |
300kV single-stage cutoff device, oscilloscope |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
400kV40kJ |
No truncation device, oscilloscope or acquisition card |
10-35KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
600kV15kJ |
600kV single-stage steepening device, acquisition card |
10-35KV level switch; And the insulator lightning impulse voltage full wave test with steep wave test requirements, waveform 1.2/50us; Steep wave |
|
600kV30kJ |
400kV single-stage cutoff device, oscilloscope |
10-66KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
500kV30kJ |
Single stage truncation device, oscilloscope |
|
|
800kV20kJ |
10-110KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors without waveform cutoff test requirements, waveform 1.2/50us |
|
|
800kV40kJ |
No truncation device, oscilloscope |
10-110KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors without waveform cutoff test requirements, waveform 1.2/50us |
|
800kV40kJ |
800kV cutoff device, oscilloscope |
10-110KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |
|
800kV80kJ |
800kV cutoff device, oscilloscope |
10-110KV level switches and insulators; And full wave lightning impulse voltage test for transformers and mutual inductors with waveform requirements of 1.2/50us; Cut wave 2-6us |