| After-sales Service: | 1 Year |
|---|---|
| Warranty: | 1 Year |
| Display Type: | Digital Only |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Working mode | can be used alone, can be used simultaneously, can be remote control and status monitoring | |||
| Applicable battery | 48V | 110V | 220V | 380V |
| Charging voltage | 40~60V | 95~150V | 190~300V | 350~450V |
| Charging current | 10~150A | 1~80A | 1~40A | 1~20A |
| Discharge voltage | 10~60V | 80~135V | 80~270V | 300~460V |
| Discharge current | 0~150A | 0~200A | 0~100A | 0~60A |
| Accuracy of current | 1% | |||
| Voltage accuracy | 0.5% | |||
| Monomer voltage accuracy | 0.2% | |||
| Monomer voltage | 0.500V~16.00V(resolution 1mv) | |||
| Charge discharge time | 0 ~ 99 hours and 59 minutes | |||
| Power supply | AC:220V/380V | |||
| Cooling way | forced air cooling | |||
| Handling way | industrial universal wheel | |||
| Heat dissipation | forced air cooling |
| Temperature | working range: -5 ~ 50ºC storage temperature: -40 ~ 70ºC |
| Humidity | relative to humidity0 ~ 90% (40±2ºC) |
| Altitude | rated altitude: 4000 m |
| Noise | <60dB |
| Voltage | single-phase three-wire system: 220V AC (- 20% ~ +30%), frequency :45 ~ 65Hz |
| Withstand voltage test | input - housing: 2200V DC 1min |
| input-output: 2200V DC 1min | |
| output - housing: 700V DC 1min | |
| Security | meet EN610950 |
| AC input | Gb socket, suitable for 1 ~ 1.5mm2cable |
| DC output | instrument 25 mm2Cable quick connect plug (red positive black negative) |




FAQ