After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Product Name: | DC Hipot Tester |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Integrated dc high voltage generator is a new generation of portable high-voltage detection instrument designed and manufactured according to China Power Industry Standard DL/T848.1-2004 "High-voltage test equipment general technical conditions Part 1: DC Integrated dc high voltage generator". Electrical insulation strength and leakage current of power devices.
The Integrated dc high voltage generator uses a high-frequency voltage doubling circuit, which uses advanced PWM pulse width modulation technology and voltage-current double-closed-loop feedback technology to improve power supply regulation and load regulation, resulting in high voltage stability and low ripple. Use imported high-power IGBT devices and their driving technology to eliminate switching interference and achieve high quality and portability of Integrated dc high voltage generator. The imported high-frequency high-voltage rectifier diode is used to make the double-press cylinder more compact and lighter, and improve the efficiency of the whole machine. According to EMI electromagnetic interference and EMC electromagnetic compatibility theory, measures such as shielding, isolation and grounding are adopted to improve the safety of the whole machine and to withstand the rated voltage discharge without damage. The instrument has complete protection functions, zero protection, over-voltage protection, over-current protection, and breakdown protection. The protection circuit uses nanosecond-level special sensors, which are fast and reliable, and effectively protect people and equipment. The over-voltage setting uses a digital dial switch, which is easy to operate and has high setting accuracy. Add intelligent high-precision 0.75U function button to facilitate the testing of zinc oxide arrester.
Integrated dc high voltage generator adopts integrated design scheme: double pressure cylinder and Host are placed in one chassis, combined with new technology, select new device, realize small size, high power, light weight, convenient operation, safe and reliable, power supply output quality The high advantage is the ideal test instrument for the high voltage test industry.
1. The output voltage is stable: the high-frequency voltage doubler circuit is applied, and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate, so that the voltage stability is high and the ripple is small.
2. comprehensive protection: full protection function, with zero protection, over-voltage protection, over-current protection, breakdown protection, protection circuit uses nanosecond-level special sensor, action fast and reliable, effectively protect personal and equipment safety.
3. 0.75U function: Add intelligent high-precision 0.75U function one-button button, press this button, the voltage and current will automatically jump to the 0.75U state, which is conducive to the test of zinc oxide arrester.
4. zero boost: The boost potentiometer starts from zero, adopts imported multi-turn potentiometer, the boosting process is stable, and the adjustment precision is high.
5. over-voltage setting: over-voltage setting uses digital dialing switch, easy to operate, and has a high setting accuracy.
6. one-piece design: the choice of integrated design, Host and double pressure cylinder is placed in a chassis. The imported high-frequency high-voltage rectifier diode is used to make the double-pressure cylinder small in size, improve the efficiency of the whole machine, and is easy to carry.
7. reliable performance: the key components use high-performance imported components, the pressure roller is coated with special insulating materials, good electrical performance, strong moisture resistance, no leakage.
8. the operation is simple: the instrument interface each function button, the layout is reasonable, the instructions are clear, easy to learn and use.
Specifications | 200/2 | 200/3 | 200/5 | 300/2 | 300/3 | 300/5 | 300/5 | 300/10 | 400/2 | 400/3 | 400/5 |
Rated voltage(kV) | 200 | 200 | 200 | 300 | 300 | 300 | 300 | 300 | 400 | 400 | 400 |
Rated current(mA) | 2 | 3 | 5 | 2 | 3 | 5 | 5 | 10 | 2 | 3 | 5 |
Rated power(W) | 400 | 600 | 1000 | 600 | 900 | 1500 | 1500 | 3000 | 800 | 1200 | 2000 |
Control box quality(kg) | 5.5 | 6.0 | 6.5 | 6.5 | 6.5 | 7.5 | 7.5 | ||||
Pressure cylinder quality(kg) | 8.7 | 9 | 9 | 11 | 11 | 11.5 | 11.5 | ||||
Double cylinder height(mm) | 970 | 970 | 970 | 1250 | 1250 | 1250 | 1250 | ||||
Voltage accuracy | ±(1.0%Reading + 2 words) | ||||||||||
Current accuracy | ±(1.0%Reading + 2 words) | ||||||||||
Ripple coefficient | ≤0.5% | ||||||||||
Voltage stability | When the power supply voltage changes by ±10%≤1% | ||||||||||
Overload capability | No-load voltage can exceed 10% of rated voltage for 10 minutes | ||||||||||
The maximum charging current is 1.25 times the rated current | |||||||||||
Power supply | Single phase communication 50Hz 220V±10% | ||||||||||
Way of working | Intermittent use: rated load 30 minutes | ||||||||||
1.1 times rated voltage usage: 10 minutes | |||||||||||
Way of working | temperature:-10ºC~+40ºC | ||||||||||
Relative humidity: no more than 85% at room temperature of 25 ° C (no condensation) | |||||||||||
Altitude: below 1500 meters | |||||||||||
With capacitive load capacity | The tested product has unlimited capacity | ||||||||||
Charged with 1.5 times rated current | |||||||||||
Structural features | Electrical insulation doubler | ||||||||||
Air insulation, no leakage | |||||||||||
Operating box features | High-precision 0.75UDC1mA one-touch button (accuracy ≤1.0%), suitable for zinc oxide lightning arrester test | ||||||||||
Overvoltage protection using digital dial switch, at a glance |