Uhv-901 All-in-One Current and Voltage Transformer on-Site Calibrator
Contact Supplier
Product Attributes
- After-sales Service
- 1 Year
- Warranty
- 1 Year
- Index Name
- Integrated Current and Voltage Transformer Field C
- Model NO.
- UHV-901
- CT Error Accuracy
- 0.02 Level
- Power Factor
- 0.0-1.0
- PT Error Accuracy
- 0.05 Level
- Power Consumption of The Whole Machine
- 30W (Static) and 150W (Working)
- Environmental Temperature
- 0-40℃
- Volume
- 472mm × 355mm × 168mm
- Environmental Humidity
- <85% at 25℃
- Weight
- 6.0kg
- Transport Package
- Wooden Case or Carton
- Specification
- CE/ISO
- Trademark
- UHV
- Origin
- China
- Production Capacity
- 200 Sets Per Month
Product Images of Uhv-901 All-in-One Current and Voltage Transformer on-Site Calibrator
Find Similar Products
Product Description
This instrument can measure the ratio and angle difference of current and voltage transformers according to national standards, and can also measure any percentage of ratio and angle difference between 1% and 200% of current; It can directly measure the transformation ratio and polarity of the transformer, etc. The instrument adopts high-precision, automatic linear adjustment DC and AC power supply; High speed and high reliability digital processing module; The high measurement accuracy and high stability of the pre measurement circuit ensure the accuracy and high stability of the instrument measurement. In addition, the instrument adopts WINCE system, 800 * 600 large LCD full English interface platform technology, user-friendly color touch screen operation, with a user-friendly human-machine interface, prompts for wiring and operation, and has any measurement parameter saving function. The machine interface is intuitive and convenient.
Products features
1,The integrated on-site tester for current and voltage transformers adopts the principle of small signal measurement. A single instrument can complete the error testing of current and voltage transformers, greatly facilitating on-site calibration of measuring devices.
2,On site verification of current and voltage transformers does not require standard current transformers, standard voltage transformers, current boosters, voltage boosters, current and voltage load boxes, voltage regulation control boxes, or high current wires. The verification of current transformers is achieved through extremely simple testing wiring and operation, greatly reducing work intensity and improving work efficiency.
3,The integrated current and voltage transformer on-site tester has a standard voltage transformer equivalent to the measured current transformer with the same transformation ratio inside, with an accuracy of 0.02 level, equivalent to a 0.05S level current transformer, accurately measuring the measured current, voltage transformer transformation ratio, and no-load error. Then calculate the error of the transformer by combining the test results of impedance and admittance.
4,Using a power supply close to the power frequency for testing, to prevent on-site power frequency electromagnetic radiation and series interference.
5,The measurement range is wide, and it can measure both standard and non-standard current transformers.
6,The accuracy of the transformer calibrator attached to the instrument can be verified using a transformer calibration device.
7,Directly integrate on-site data and determine whether it is qualified or unqualified
8,Measure the standard variable ratio current transformer and measure the standard variable ratio current transformer with a specification point error (angle difference, ratio difference) of 1% -120% (S-level).
9,Measure any point error (angle difference, ratio difference) of 1% -200% (S-level) between standard and non-standard ratio current transformers.
10,Measure and display the standard points and any point errors (angle difference, ratio difference) of the current transformer under the upper and lower limit loads.
11,One measurement and display of the actual regulation point and error (angle difference, ratio difference) of the current transformer under any load.
12,Detect the polarity and transformation ratio of known and unknown current transformers, and be able to determine the actual current ratio of unknown current transformers. It can also vaguely determine whether the secondary current of unknown current transformers is 5A or 1A.
13,Meet the requirements of 20% -120% standard point error (angle difference, ratio difference) detection for measuring voltage transformers in accordance with national regulations.
14,Complete the measurement in one go and display (according to the regulations) the standard point error (angle difference, ratio difference) of the voltage transformer under the upper and lower limit loads.
15,Complete the measurement and display the standard point error (angle difference, ratio difference) of two sets of voltage transformers under any actual load in one go.
16,Detect the transformation ratio and polarity of the voltage transformer.
17,It has intelligent judgment of external wiring status, indicating wiring errors, transformation ratios, polarity errors, etc. Automatically round the test data and determine if it exceeds the tolerance.
18,800 * 600 large screen LCD display, fully Chinese interface. Easy wiring and operation, convenient to carry.
19,Various measurement data can be stored on-site for convenient user queries.
20,The instrument is conveniently connected to a computer through a standard USB interface to transfer data, and the backend management software processes reports and prints certificates according to national standards.
21,The chassis should be made of shockproof and pressure resistant materials to ensure the safety of on-site operators and equipment.
22,The overall weight of the machine is less than 6.0Kg, and the overall volume is 472mm × 355mm × 168mm. The small volume and light weight make it truly easy to carry.
Product Parameter
(1)
| CT ratio range | 5A/5A~25000A/5A (5A/1A~5000A/1A) turn ratio error ± 0.2% |
| Error measurement range | 5A/5A~5000A/5A(5A/1A~5000A/1A) |
| Accuracy range of the tested current transformer | 1.0, 0.5, 0.5S, 0.2, and 0.2S |
| CT error accuracy | 0.02 level |
(2)
| PT ratio range | Full range measurement (electromagnetic type) ± 0.2% |
| Error measurement range | Primary voltage:3-220kV/(non-standard primary voltage is also acceptable) Secondary voltage: 3kV/100V,3kV//100V/;6kV/100V,6kV//100V/;6.3kV/100V, 6.3kV//100v/;10kV/100V,10kV//100V/;10.5kV/100V,10.5kV//100V/;13.8kV/100V,13.8kV//100V/;15kV/100V,15kV//100v/;15.75kV/100V ,15.75kV//100V/;18kV/100V,18kV//100V/ ;20kV/100v, 20kV//100v/;35kV/100V,35kV//100V/;66kV//100v/; 110kV//100V/;220kV//100V/ |
| Power factor | 0.0-1.0 |
| PT error accuracy | 0.05 level |
| DC resistance | 0.0-0.1 Ω ± 3% |
| 0.1-50Ω ±1% | |
| Environmental temperature | 0-40ºC |
| Power consumption of the whole machine | 30W (static) and 150W (working) |
| Environmental temperature | 0-40ºC |
| Environmental humidity | <85% at 25ºC |
| Whole machine weight | 6.0Kg |
| Whole machine volume | 472mm × 355mm × 168mm |
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR239794". Items marked "" are certified.
Company Profile
Wuhan UHV Power Technology Co., Ltd., established in 2021, located in Wuhan East Lake New Technology Development Zone is also named Wuhan Optical Valley with convenient transportation access. And We have self-operation export and import rights.
Our company is a professional OEM Manufacturer which is engaged in the research, development, sale and service of AC Series Resonant System, High Voltage Tester, Transformer Tester, Relay Protection Tester & Oil Testing Equipment,
We have wide range of production line more than 108 different kinds of products in high voltage testing area. There are widely applied in electric power energy, transportation, metallurgical, chemical, mining and water conservancy project.
Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction. In addition, we have obtained ISO9001, ISO14001, ISO45001 & other certificates. Selling well in all cities and provinces around China, our products are also exported to clients in such countries and regions as Malaysia, Indonesia, Vietnam, Philippines, America, Australia, Argentina, Brazil and exported to about 100 countries.
We always try best to supply a professional solution for our clients and our service are recognized and highly appreciated by world scale customers, we will always right be here takes the customer as first priority and provide you the best solution. Looking forward to building a thrust-worthy and long-term relationship with you.
Our slogan: Smart Electric Testing Equipment Manufacturer, making your testing work more easier.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- Building 6, Optics Valley Optical-Mechanical Industrial Park, No.83, Gaoxin 5th Road, East Lake High-Tech Zone, Wuhan, Hubei, China
-
Plant Area
- 4800 square meters
-
Number of Employees
- 111
-
Registered Capital
- 10,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shanghai Port, Wuhan Port, Shenzhen Port, Ningbo Port
-
Minimum Order Quantity
- 1 Set
-
Supply Chain Partners
- 17
Our Production Capability & Technical Expertise
-
Main Products
- Contact Resistance Tester, Protection Relay Tester, Circuit Breaker Analyzer, AC DC Hipot Tester, Transformer Tester, Series Resonant Test System, VLF Hipot Tester
-
Production Lines
- 1
-
Production Machines
- Backup Line Protection Device, Density Relay Calibrator Verification Device, Digital Capacitance Protection Measurement, Digital Multimeter, Hot Glue Gun, Multimeter, Oscilloscope Equipment, Soldering Iron, Bench Drill
-
QA/QC inspectors
- 5 people
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instructions and uniformly followed
-
Customization Options
- Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 4 people
-
Traceability of Raw Materials
- Yes
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2021-03-15
-
Export Year
- 2 Years
-
Main Markets
- North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia, Domestic
-
Repeat Buyers Choice
- 30%~50%
-
Number of Foreign Trading Staff
- 6
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- Yes
Our Certifications, Standards & Industry Recognition
-
Product Certification
- CE
-
Cooperated with Fortune 500
- Yes
Send your message to this supplier
People who viewed this also viewed
-
US$1,900.00-3,300.00 / Set
-
US$10,000.00-30,000.00 / Set
-
US$2,300.00-8,500.00 / Set
-
US$2,000.00-6,600.00 / Set
-
US$700.00-5,800.00 / Set
-
US$590.00-4,900.00 / Set
-
US$10,000.00-30,000.00 / Set
-
US$10,000.00-30,000.00 / Set
-
US$5,000.00-40,000.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- Transformer tester
- Others Transformer tester
- Uhv-901 All-in-One Current and Voltage Transformer on-Site Calibrator
Related Categories
Hot Searches
- China Instrument
- Optical Instrument Factories
- Electronic Instrument Factories
- Control Instrument Factories
- China Calibration
- Instrument Calibration
- Instrument Calibration Equipment
- Calibration Device
- Manual Calibration
- Top 10 Instrument
- Instrument Trends
- Transformer Field Calibration Instrument Bulkbuy